Installation Details
Connections: Inlet/Outlet. 22mm compression fittings/3/4" BSP parallel thread.
Cold Water Control: Integrated cold water control set comprising pressure reducing valve and strainer- factory set at 3.5 bar, expansion relief valve - factory set at 6 bar and check valve. 22mm compression fittings. Tundish (supplied as part of kit) - 15mm compression Inlet and 22mm compression outlet.
Compatible Boilers: Gas or Oil fired – open vent or sealed system type, fitted with integral control thermostat and cut-out.
Electrical: Direct Models: Connection is via a terminal block housed within the integrated controls housing. The electrical supply must be permanently connected via a double pole linked isolating switch with a minimum break capacity of 13A. Indirect models: Controls should be wired to the boiler, programmer etc. in accordance with the control scheme being used. The unit is suitable for ’S’ Plan control systems. For ‘Y’ Plan systems a relay is required. This is available as an accessory – Part No 94 970 034 All electrical wiring must conform to the latest IEE Wiring Regulations.
Flow Rates: Up to 55 ltrs per minute, @ 6 bar pressure.
Guarantee: On-site service support from date of purchase. Cylinder – 25 years. Expansion vessel – 5 years. Element and other controls – 2 years.
Minimum Water Supply Reqmnts: Recommended minimum supply pressure – 1.5 bar/20 l/min flow rate. If there are any doubts about water supply pressure or flow rates, please contact our Specification Advice Team to discuss.
Plumbing: 22mm compression fittings.
Pressure Testing: Units are tested to 15 bar.
Safety Valve: Temperature and pressure relief valve, factory set to operate at 10 Bar and 90°C.
Safety Valve Discharge: 15mm compression outlet.
Secondary Circulation: Via 22 x 22 x 15mm swept tee, which should be fitted to the inlet pipework. A swept tee is available as an optional accessory – part No 94 970 033
Tundish: Tundish (supplied as part of kit) - 15mm compression Inlet and 22mm compression outlet.
Temperature Relief Valve: Factory fitted
WaterExpansion: Remote expansion vessel – 12 ltr vessel supplied with 100, 120 and 150 ltr models. 18 ltr vessel supplied with 170 and 210 ltr models. 25 ltr vessel supplied with 250 and 300 ltr models.
|
Specification
Anode: No anode to maintain or replace.
Approvals: WRAS and BEAB Approved WRC approved for Building Regulation G3
Capacities: Model Litres Ref. Nom. PP100 100 PP120 120 PP150 150 PP170 170 PP210 210 PP250 250 PP300 300
Controls: A fittings kit is supplied with every PremierPlus and comprises an expansion vessel and all valves necessary to ensure safe installation. Kits for indirect models include a ‘2 port’ motorised valve.
Factory Safety: Temperature and Pressure Relief Valve
Guarantee: 25-year transferable cylinder guarantee - conditions apply. 5-year guarantee on the coldwater control valve 5 year guarantee on expansion vessel 2-year guarantee on all other components Element and other controls - 2 years.
Outer Casing: Plastisol coated, corrosion proofed steel with grey, high impact thermoplastic, moulded top and bottom covers.
Primary Coil: 22mm diameter, stainless steel. 'Coil-in-coil' design for improved performance.
Rating: Element rating Indirect units 1 x 3.0 kW (240V). Direct units 2 x 3.0 kW (240V) (1 x 3.0 kW PP100E). Note:- PP250E & PP300E - a 3rd element boss is supplied blanked off to enable an additional 3kW @ 240V element to be fitted if required. For additional element, order Code No. 94 970 036 PP250B & PP300B - a second element boss in the boost position is supplied blanked off to enable a an additional 3kW @ 240V element to be fitted. For additional element, order Code No. 94 970 036
Safety Features: All Models: Temperature and pressure relief valve, factory set to operate at 10 Bar and 90°C. High limit thermostat, factory set at 80°C. Direct Models: Manually re-settable cut-out, set to 80°C.
Sheath: Alloy sheathed element, incorporated into an easily removable heater plate, should replacement be necessary.
Thermal Insulation: CFC/HCFC free (ODP Zero) fire retardant expanded polyurethane. 45mm thick. GWP 3.1 (Global Warming Potential) Standing Heatloss Figures (kWh/24h) PP100 1.14 PP120 1.25 PP150 1.45 PP170 1.63 PP210 1.96 PP250 2.45 PP300 2.72
Thermostat Spec: Element thermostat adjustable from 10°C to 70°C.
Water Container: High-grade Duplex stainless steel, pressure tested to 15 Bar.
|
|
For More Information Please Click On One Of The PDF'S

|