Hot Water Cylinders
0 ITEM(S) IN YOUR BAG / TOTAL:£0.00 view cart
Unvented Indirect Hot Water Cylinders
Unvented Direct Hot Water Cylinders
Solar Powered Hot Water Cylinders
Accumulators
Cylinder Accessories
RM Direct Solar Unvented Cylinder 150ltr Mega Flow Stainless Steel 25 Year Guarantee
15289 RM Direct Solar Unvented Cylinder 150ltr Mega Flow Stainless Steel 25 Year Guarantee
Gledhill Stainless Lite Unvented Indirect Water Cylinder 300 Litres
13430 Gledhill Stainless Lite Unvented Indirect Water Cylinder 300 Litres
Gledhill Stainless Lite Unvented Indirect Water Cylinder 150 Litres
13426 Gledhill Stainless Lite Unvented Indirect Water Cylinder 150 Litres

Home > Range Information Page
Range Information Page
WELCOME TO RANGE CYLINDERS
 
What We Do
The biggest name in hot water storage for over eighty years, manufacturing copper cylinders combination units, and high performance 'Duplex' Stainless Steel unvented units in over four hundred different sizes, types and patterns.
 
Every Range product is manufactured to the highest standards, ensuring the unrivalled quality you have come to expect from us. We also take great pride in giving our customers a service second to none.
 
Products
Please select your product/product range from the list below in order to be directed to the relevant information that you are searching for. If you are unable to find what you are looking for we suggest using our product selection guide, using the site map, or calling one of our team at Range HQ.
 Meet The Family
 

For over 80 years, Range have been synonymous with quality. The Range brand has embodied all the hallmarks of manufacturing excellence and product innovation.

All Range factories work to and are accredited to ISO 9001

Exhaustive research and development has culminated in the new Tribune HE family of Duplex stainless steel unvented cylinders. Tribune aims to set new benchmarks for quality, performance and endurance.

With 25 models in its product range, there is sure to be a Tribune HE capable of fulfilling your needs today and long into the future.

> Duplex stainless steel for ultimate peace of mind
> Fully transferable 25 year guarantee
> High flow-rate controls - ideal for multiple bathrooms & power showering
> Fast reheat and high insulation values resulting in high efficiency
> A Complete package - just add pipework
> Electric/Direct and Gas-Oil/Indirect
8 sizes 60-300 litres
Twin Coils - Solar etc 4 sizes 180-300 litres
Slimline - 6 sizes 60-210 litres
> Plug-in, Pre-plumbed units available, saving extra time and providing continuity on multiple installations.

 
 
 
Duplex Stainless Steel - The Only Option
Duplex stainless steel, for so long reserved for the intense demands of chemical plants, forms the heart of every Tribune HE unit. Duplex offers superior corrosion resistance to copper, glass-lined steel and other lesser grades of stainless steel, particularly in aggressive water areas.
Duplex stainless steel is a special combination of Austenitic and Ferritic stainless steels. Its low-carbon, high-chromium composition is allied to careful design and state-of-the-art TIG welding equipment in our multi-million pound factory.
As a result Tribune HE is resistant to all forms of corrosion including crevice-corrosion, pitting-corrosion, uniform-corrosion and stress corrosion cracking. Tribune's superior corrosion performance is achieved without an anode and its associated maintenance worries.
Duplex stainless steel has a superior strength-to-weight ratio to copper or glass-lined steel. The Tribune HE has higher pressure ratings than copper whilst typically weighing less than half that of an equivalent glass-lined steel unit.
Duplex Stainless and The Environment

Duplex stainless steel is extremely environmentally friendly. As a material it is 100% recyclable in fact over 90% of new stainless steel comes from old re-melted stainless steel. Stainless steel will go on to complete full life cycles indefinitely.

Fully Transferable 25 year guarantee

All Range Tribune HE units are sure to offer their user a long operational life and with the absence of a sacrificial anode to inspect maintain or replace, costs are reduced. The units are backed by our fully transferable 25 year guarantee. No customer registration is required to validate the guarantee.
 
lots of powerful hot water
 
hour after hour, day after day, month after month... year after year!
 
Some applications simply require the best the market has to offer. In such a case specify a Range Tribune HE. No home need to be without the outstanding user benefits that come as standard with every Tribune HE cylinder. Fantastic flow rates, assured reliability and extremely low running costs are just some of the benefits. The Tribune HE is extremely flexible in terms of siting and will furnish powerful mains pressure hot water to multiple points around the home.
The Tribune HE is extremely flexible in terms of siting and will furnish powerful mains pressure hot water to multiple points around the home.
Choose Range Tribune HE - a cylinder for life!
 
 
>
Mains Pressure
- Powerful Showers
 
 
 
>
High Flow Rates
- Baths fill extremely quickly
 
 
- Ideal for multiple bathrooms
 
 
 
>
Fast Reheat Times
- Hot water always available
 
 
 
>
Very Well Insulated
- Low heat loss
 
 
- Economical to run
 
 
 
>
Stove Enamelled Steel Case
- Smart, tough and wipe clean
 
 
 
>
Low Maintenance
- No hidden costs
 
 
 
>
25 Year Fully Transferable Guarantee
 
 
- Peace of mind

Its Strength Is In Its Detail...

The beauty of the Range Tribune HE is not only skin deep. Take a look inside. See for yourself how we've combined the highest manufacturing standards with tried and tested values, control sets and thermostats from renowned manufacturers.

1. Appliance Quality Finish.
2. High quality Duplex stainless steel cylinder - pressure tested to 15 bar.
3. Totally insulated with 50mm thick HCFC & CFC free foam, exceeding CHESS best standards. ODP Zero & GWP One.
4. Long-life & quiet incoloy immersion heater.
5. 22mm hot water outlet.
6. 22mm coil connections.
7. Primary coil in coil heat exchanger.
8. Wide range of models from 60 litres to 300 litres.
9. Slimline model when space is restricted.
10. Temperature and pressure relief valve operating at 90"c/7 bar.
11. High quality controls.
 
The Range Control Set
The inlet control set on every Tribune HE units is of a well-proven 'high-flow' design, allowing flows in excess of 50L/min.
The set combines a pressure reducing valve, complete with strainer, non-return valve and expansion relief valve with provision for expansion vessel and balanced cold connections.
The operating pressure is 3 bar, but the valve will continue to give good performance down to an inlet pressure of 1 bar.
Coil-in-Coil Heat Exchanger
With its large surface area you are assured of fast reheats. The smaller sizes of Tribune HE exceed the CheSS best practice guidelines.
Either coil connection can be used as the inlet. Reheat performance is equally good either way.
In reaching right down to the bottom of the cylinder, the coil-in-coil heats the Tribune HE's entire capacity. A sophisticated cold water baffle helps preserve the stratification and prevent mixing during water draw-off. As a result, a 150 litre Tribune HE produces 150 litres of hot water - as simple as that!
Environmentally Friendly Insulation
As you would expect, Tribune HE is very well insulated. A class leading 50mm thick insulation layer surrounds the cylinder. Coupled with the close-fitting case, Tribune HE's heat loss is low.
Heat loss figures meet CheSS best practice guidelines for insulation.
The insulation is CFC-Free, HCFC-Free and contains no ozone-depleting chemicals.
External Expansion Vessel - Flexible and Reliable
We have chosen to use an external expansion vessel for our Tribune HE. With no air bubble to lose it promises improved reliability. Add flexible siting and reduced overall height and you have a winning combination.
Comprehensive kit of parts with every unit
We've not cut corners in our kit of parts. You get all the components you need to complete the installation - just add pipework.
This attention to detail means no lost time making a trip to the merchants and no hidden costs involved when you buy a Tribune HE.
Expansion Vessel
Part Nos.:
12 Litre - TS312
18 Litre - TS318
24 Litre - TS325
Expansion
Vessel Hose
Part No. TS314
 
 
 
 
Wall Mounting Kit
for Expansion Vessel
Part No. TS316-12L
Expansion Vessel Bracket
Part No. TS317-18/24L
 
 
High Flow Rate
Inlet Control Set
Part No. TS301
 
 
 
 
10 Way
Electrical Box
Part No. TS106
 
 
V4043H
Two Port Valve
Part No. TS5
 
 
 
 
Temperature and
Pressure
Relief Valve
Part No. TS302
 
 
Incoloy Long Life
3kW Immersion
Heater
Part No. TS9
 
 
 
 
Acetal Tundish
Part No. TS303
 
 
Installation &
Maintenance
Instructions
 
 
 
 
Dual Thermostat
Part No. TS207
 
 
Benchmark
Logbook
 
 
 
 
Twin Coil Only
 
 
 
 
Single Thermostat
Part No. TS27
 
 
HL Thermostat
Part No. TS28
Tribune HE comes complete with all the fittings you need to complete the installation:
DIRECT PARTS (ELECTRIC)
> Inlet Control set
> Temp & Pressure relief valve
> 15mm / 22mm Tundish
> Expansion vessel
> Wall mounting bracket
> Expansion vessel hose
> 2 x Immersion Heaters (1 on 60L and 90L)
> Installation & Maintenance Instructions
> Benchmark Logbook
INDIRECT PARTS (GAS/OIL)
> Inlet Control set
> Temp & Pressure relief valve
> 15mm / 22mm Tundish
> Expansion vessel
> Wall mounting bracket
> Expansion vessel hose
> Immersion Heater (2 on 250 & 300 litre)
> Two port zone valve
> Wiring centre
> Dual Thermostat
> Installation & Maintenance Instructions
> Benchmark Logbook
 
TWIN COIL PARTS (RENEWABLE ENERGY SOURCE)
> Inlet Control set
> Temp & Pressure relief valve
> 15mm / 22mm Tundish
> Expansion vessel
> Wall mounting bracket
> Expansion vessel hose
> Immersion Heater
> 2 x Two port valves
> Wiring centre
> Dual Thermostat
> Single Thermostat
> High Limit Thermostat
> Installation & Maintenance Instructions
> Benchmark Logbook
For Parts and Spares ring 01924 376026

Using Tribune HE Units In Parallel

For applications where very high flow rate or larger amounts of storage are required two or more Tribune HE units can be linked in parallel.

When linking two cylinders a serparate cold feed is taken to each one and the outlets are joined together. The flow rate available doubles (subject to the cold main).

The demand for hot water will vary considerably between types of buildings and the activities taking place there.

For example:

An office building will require small quantities frequently to many outlets during normal & overtime office hours.

A factory production line will have a peak demand at the breaks in the shift or at the end when the work force may all want to wash their hands simultaneously.

A Sports Pavilion will need to be able to provide large quantities of hot water for the teams showering needs over a short period of time after the game.

So your selection must take into account a number of things:

1. The maximum simultaneous hot water demand

2. The total hot water demand required

3. The required system reheat time

http://www.hot-water-cylinders.com/Range-Tribune-HE_c_990-1.html

Applications Using Tribune HE Solar Units

Also suitable for other renewable energy sources
Twin coil Tribune HE's can be used in various ways:
1) To couple two different boilers up to the Tribune HE
2) For systems with solar heating. Solar heat is fed in via the lower coil.
3) Heat pump
4) Bio-mass
5) Micro-CHP
IMPORTANT NOTICE
It is a requirement of building regulations that any heat source connected to an Unvented cylinder (such as Tribune HE) be under full thermostatic control and are able to turn themselves COMPLETELY off
As a result you cannot connect an Aga (or equivalent) or a solid fuel stove to a Tribune HE.
 

Domestic Selection Guide
 

These recommendations are based on guidelines in BS 6700.

Guidance should be sought for unusual applications.
E.g. High flow-rate showers, large baths etc.

 
Hot Water Demand Bedrooms Gas/Oil
Indirect
Electric
Direct
       
1 Bathroom or Shower Bedsit / 1 Bed 60/90/100 150
  2-3 Bed 120 180
  3-4 Bed 150 210
       
1 Standard Bath 2-3 Bed 120 210
  3-4 Bed 120 210
       
2 Bath and En-suite 2-3 Beds 150 210
  3-4 Beds 150 210
  4-5 Beds 180 250
       
2 Standard Baths 2-3 Bed 180 210
  3-4 Bed 180 210
  4-5 Bed 210 250
       
3 Bathrooms 3-4 Bed 250 300
  4-5 Bed 250 300
  5-6 Bed 300 300
 
Commercial Selection Guide
 
Typical commercial application
Indirect
 
 
Large House - 6 bed / 4 bathrooms
2x 210
Guest House - 8 bed / 4 bathrooms
2x 300
Small Hotel - 8 bed / 8 bathrooms
3x 210
Sports Pavillion (25 people / 4 showers)
2x 300
Sports Pavillion (25 people / 6 showers )
3x 210
Student House (25 people / 3 bathrooms)
3x 300
Old Peoples' Home (60 beds / 10 bathrooms)
5x 300 each supplying 2 bathrooms
Example illustration
A school swimming pool has 5 showers in each of two changing rooms. The shower heads are flow-restricted to 9 ltrs per minute (2/3rds of this will be hot water). Usually there are 3 one hour lessons each morning and three each afternoon. Assuming a class size of 30 children.
Maximum demand = 10 shower heads x 9 litres / min = 90 litres / min. This is more than one Tribune HE can supply. At least two Tribune HEs will be needed to provide this ( see flowrate graphs )
Total demand = 30 kids x 6 litres / minutes x 5 minute shower = 900 litres
3x 300 litre units will be required
Reheat time has to be a maximum of one hour so it is reheated in time for the next lesson.
A TI300 can reheat its entire contents in 60 minutes with a boiler power of 15kW. So total boiler power required = 45kW
If direct units were used it would have to be fitted with immersion heaters rated at 15kW (typically 1 x 9kW + 1 x 6kW)
 
Installation
 
  

Regulations

All unvented units with a capacity over 15L capacity must be installed by a competent installer in accordance with the following Regulations:

England and Wales - Building Regulation G3
Scotland - Technical Standard P3
N Ireland - Building Regulation P5

Siting
With no header tanks to consider, Tribune HE units can be sited almost anywhere in the house. Tribune HE can supply outlets both above and below its location. Tribune HE must be fixed VERTICALLY on a flat surface capable of holding its weight.
 
Water Supply
An adequate water supply is vital to ensure Tribune HE produces the high performance of which it is capable. We recommend a minimum supply of 1.0 bar with a flow rate of 25 litres/min. The maximum supply pressure is 16 bar.
 
Compatible Boilers
Gas or oil fired fitted with an integral control thermostat and cut-out. Any heat source that lacks full thermostatic control such as most solid fuel boilers, Agas, Rayburns and Stanleys cannot normally be connected to any unvented system.
The Primary circuit may be Open Vented or Sealed (operating at up to 7 bar). The primary circuit must be pumped.
 
Connection Sizes
Cold Inlet - 22mm compression.
Hot Outlet - 22mm compression.
Coil connections - 22mm compression.
Safety Valves - 15mm compression outlet.
Inlet Control Set - 22mm compression inlet and outlet.
Tundish - 15mm compression inlet / 22mm compression outlet.
 
Secondary Return
A dedicated 22mm secondary return connection is fitted to 210, 250 and 300 litre sizes. A swept tee (not supplied) could be used to provide a secondary return on the smaller sizes.
 
Electrical Wiring
Controls should be wired to the boiler / programmer etc. in accordance with the control scheme being used. Although compatible with Y, W or S Plan layouts, Tribune HE units are perhaps best suited to installation as an S Plan since we already supply one of the two port valves necessary, so reducing installation costs compared to other plans.

Each immersion heater must have a permanent connection via a double pole-linked isolating switch with a minimum rating of 13 amps. All electrical wiring must comply with the latest IEE wiring regulations.

 
Performance Indirect Reheat Performance
 
Model
Reheat Time
Coil kW Rating
60
11 minutes
16.5kW
90
13 minutes
16.5kW
120
17 minutes
16.5kW
150
17 minutes
18.9kW
180
21 minutes
18.9kW
210
22 minutes
18.9kW
250
28 minutes
21.4kW
300
36 minutes
21.4kW
The reheat performance is measured from 15°C to 60°C after drawing off 70% of the capacity.
The coil kW rating is a guide to the minimum size of boiler required to achieve the reheat times stated.
direct reheat performance

 
Model
Reheat Time
Coil kW Rating
 
one element
two elements
60
45 minutes
-
90
35 minutes
-
100
58 minutes
-
120
90 minutes
45 minutes
150
121 minutes
62 minutes
180
157 minutes
79 minutes
210
192 minutes
96 minutes
250
224 minutes
112 minutes
300
263 minutes
132 minutes
 
immersion heaters
Tribune is fitted with Immersion Heater as follows:

 
Size
Direct
Indirect
Twin Coil
90 Litre
One Immersion Heater
One Immersion Heater
Not Made
120 Litre
Two Immersion Heaters
One Immersion Heater
Not Made
150/180/210 Litre
Two Immersion Heaters
One Immersion Heater
One Immersion Heater
250/300 Litre
Two Immersion Heaters
Two Immersion Heaters
One Immersion Heater
 
flow rates

Tribune Unvented Pressure V Flow Performance
(measured at 50% Backpressure to simulate the effect of the drawoff pipework and taps)

Direct Specification

Code
Capacity
Height
Diameter
D
F
Weight
Weight
 
 
 
 
 
 
(kg-empty)
(kg-Full)
 
 
 
 
 
 
 
 
TD90
90 L
718
550
N/F
N/F
25
115
TD120
120 L
906
550
N/F
510
30
150
TD150
150 L
1093
550
N/F
610
35
185
TD180
180 L
1281
550
N/F
710
40
220
TD210
210 L
1469
550
1000
810
45
255
TD250
250 L
1719
550
1250
950
50
300
TD300
300 L
2032
550
1500
1100
55
355
 

Indirect Specifications
 
 
Code
Cap.
Height
Dia.
A
B
C
D
E
F
Weight
Weight
 
 
 
 
 
 
 
 
 
 
(kg-empty)
(kg-Full)
 
 
 
 
 
 
 
 
 
 
 
 
TI90
90 L
718
550
290
330
390
345
N/F
N/F
30
120
TI120
120 L
906
550
290
330
390
345
N/F
N/F
35
155
TI150
150 L
1093
550
330
370
465
385
N/F
N/F
40
190
TI180
180 L
1281
550
330
370
465
385
N/F
N/F
45
225
TI210
210 L
1469
550
365
405
465
465
N/F
1150
50
260
TI250
250 L
1719
550
365
405
465
560
950
1400
55
305
TI300
300 L
2032
550
365
405
465
660
1100
1600
60
360
 
 
Tribune HE Solar
 
CODE
CAPACITY
HEIGHT
DIAMETER
A
B
C
D
E
F
WEIGHT
(Kg-EMPTY)
WEIGHT
(Kg-FULL)
TT180
180 L
1281
550
330
385
465
N/F
825
880
50
230
TT210
210 L
1469
550
365
420
465
775
925
980
55
265
TT250
250 L
1719
550
365
420
465
1250
1050
1105
60
310
TT300
300 L
2032
550
365
420
465
1500
1200
1255
65
365
http://www.hot-water-cylinders.com/Range-HE-Solar-Cylinders_c_992-1.html
 
 
Slimline Units

Indirect

CODE
CAPACITY
HEIGHT
DIAMETER
A
B
C
D
WEIGHT
(KG-EMPTY)
WEIGHT
(KG-FULL)
TIS60
60 L
673
478
290
330
390
345
25
80
TIS90
90 L
1048
478
290
330
390
345
30
130
TIS120
120 L
1236
478
290
330
390
345
35
155
TIS150
150 L
1424
478
330
370
470
470
40
190
TIS180
180 L
1674
478
330
370
470
560
45
225
TIS210
210 L
1987
478
330
370
470
660
50
260

http://www.hot-water-cylinders.com/Indirect_c_996-1.html

Direct

CODE
CAPACITY
HEIGHT
DIAMETER
F
WEIGHT
(KG-EMPTY)
WEIGHT
(KG-FULL)
TDS60
60 L
673
478
N/F
-
-
TDS90
90 L
1048
478
600
25
115
TDS120
120 L
1236
478
700
30
150
TDS150
150 L
1424
478
800
35
185
TDS180
180 L
1674
478
900
40
220
TDS210
210 L
1987
478
1100
45
255

http://www.hot-water-cylinders.com/Direct_c_995-1.html

 
Tribune HE System Fit
 
 
Save time and money with Tribune HE Systemfit, plug-in and pre-plumbed units
The Ultimate plug-in, Pre-Plumbed Solution
Tribune HE is available in a highly popular plug-in, pre-plumbed format - designed to significantly reduce the installation time. The units are factory assembled and are both pre-plumbed and pre-wired with 230V central heating controls, a pump, two 2-port motorised valves, automatic bypass and a balancing valve. All units are also supplied with programmer, room stat and both a central heating & hot water expansion vessel pack.
This pre-plumbed Tribune HE System will not only speed up the installation process, but will also increase the quality and integrity of the central heating system. This results in an elimination of costly call-backs.
 
 
Features And Benefits
 
features
> 120, 150, 180, 250, and 300 litre capacities - s-plan 
> Seven day programmer and room thermostat with timed domestic hot water (DHW) control 
> Seperate central heating and hot water zones 
> No maintenance three speed circulating pump 
> Automatic bypass valve for system efficiency 
> Load balancing valve for indirect coil efficiendy 
> Connections for vented and unvented heating primaries. 
>Plug in electrical connections for all controls
benefits
> Simplified on-site installation 
> Up to 70% quicker to install 
> Factory assembled for reliability - reduces costly call-backs and delays 
> Consistent electrical and plumbing layout - neat, professional finish 
> Greater customer satisfaction 
> ISO 9001:2000 quality assured 
> 25 year guarantee 
> No tanks in the roof space & only requires a standard boiler 
> Aids with Part P (Electrical wiring) as installer doesn't need an electrician on site to change any components, simply plug & go!
 
 
Specification List
 
The pre-plumbed Tribune HE System is manufactured from high grade materials inside and out, offering exceptional performance and reliability.
ISO 9001:2000 Quality assured assembly
> Consistent electrical and plumbing layout
> Brazed pipework fabrication
> Neat and tidy layout
> Pre-wired and pre-plumbed
Separate Central Heating and Hot Water Configuration
> 22mm motorised valve to radiator circuit
> 22mm motorised valve to coil heat exchanger
> Wiring centre
> Seven day programmer and room thermostat with timed Domestic Hot Water (DHW) control
> Hot water temperature thermostat
High Performance Configuration
> Automatic bypass valve
> 3 speed circulator pump with high quality isolating valves
> Balancing valve
> 22mm cold water combination valve (supplied loose)
> Combined expansion valve/check valve housing
> 22mm of 3/4" BSP hot outlet to taps
> 22mm primary flow
> 22mm primary return
> Immersion heater with integral thermostat and thermal cut-out
> Drain cocks
> Comes complete with central heating expansion vessel pack and pressure gauge, as per inset shot below
Comprehensive Safety Controls
> Temperature and pressure relief valve operating at 90oC / 10 bar
> 22mm tundish outlet
> High limit hot water thermal cut-out
 
 
Technical Specifications
 
 
Connections
1. 22mm hot water draw
2. Cold Water Inlet
3. Temperature Relief Valve
4. Cold Feed Drain Elbow
5. Immersion Heater 3kW
6. Twin Thermostat
7. Flow from Boiler
8. Circulating pump
9. 22mm Central Heating 2 port valve
10. Filling Loop Flexible Hose
11. Bottle Air Eliminator
12. 22mm DHW 2 Port valve/safety valve
13. Heating circuit drain elbow
14. 22mm Balancing valve (Lockshield)
15. 22mm Return from radiator circuit
16. 22mm Return to boiler
17. 22mm Automatic by-pass valve
18. Wiring Centre
19. Tundish
Plug-in sockets
Code
Capacity
Height
Diameter
Weight
Weight
 
 
 
 
(Kg-empty)
(Kg - full)
 
 
 
 
 
 
TI120P
120 L
906
550
45
165
TI150P
150 L
1093
550
50
200
TI180P
180 L
1281
550
55
235
TI210P
210 L
1496
550
60
270
TI250P
250 L
1719
550
65
315
TI300P
300 L
2032
550
70
370
All Dimensions are in mm and are of the cased unit. N/F = not fitted. * More detailed information regarding the connection heights is available on request.
 
 
Specification Summary
 
 
Materials
Inner shell - Duplex Stainless Steel
Coil - 22mm Diameter Stainless Steel
Bosses - Stainless Steel
Every Tribune HE is water tested to a pressure of 15 bar.
 
Insulation
Fire retardant polyurethane foam, nominal thickness 50mm.
The foam is CFC-Free and HCFC-Free.
The foam has an ozone depletion potential of ZERO and a Global Warming Potential of One.
 
Casework
Zintec corrosion proofed steels throughout
Durable, stove enamelled, gloss white paint finish
 
Anode
None fitted / none required
Expansion Vessel
12 Litre size with 60, 90, 120 and 150 Litre models
18 Litre size with 180, 210 and 250 Litre models
25 Litre size with 300 Litre model
 
Control Settings
Pressure Reducing Valve - 3 Bar
Expansion Relief Valve - 6 Bar
Pressure and Temperature Relief Valve - 7 Bar/90°C
High Limit Thermostat in Dual Thermostat - 85°C
High Limit Thermostat in Immersion Heater - 85°C
 
Immersion Heater
13/4" BSP Parallel Threaded Head
Long Life Incoloy Sheathed Low Noise Element 14" Long
Long Life Incoloy Sheathed Thermostat Pocket 11" Long
Brazed Construction
11" Combined Thermostat and Safety Cut-Out
Element Rating 3Kw at 240V A/C
 
Approvals
WRAS Approved to the Water Regulations
WRC-NSF Approved to Building Regulations' G3 & L
CE Compliant and fitted with a BEAB Approved Immersion Heater
 
Guarantee Terms
The Tribune HE's stainless steel vessel carries a fully transferable, 25 year guarantee against faulty materials or manufacture provided that:
It has been correctly installed as per the Installation Instructions and all the relevant standards, regulations and codes of practice in force at the time.
It has not been modified in any way, other than by Range.
It has not been misused, tampered with or subjected to neglect
It has only been used for the storage of potable water.
It has not been subjected to frost damage.
The unit has been serviced annually
The benchmark log book has been filled in after each annual service.
The guarantee period starts from the date of purchase and no registration is required.
Please note that invoices for servicing may be requested to prove that the unit has been serviced annually.
All the components fitted to / or supplied with the Tribune HE carry a 2 year guarantee.
 
Exclusions - The Guarantee does not cover
The effects of scale build up.
Any labour charges associated with replacing the unit or its parts
Any consequential losses caused by the failure or malfunction of the unit.