PULLIN EVOLUTION TECHNICAL SPECIFICATION
Nominal Capacities 100, 120, 150, 170, 210, 250 & 300 litres.
Element Long-life Incoloy 800 sheathed element, incorporated into an easily removable heater plate, should replacement be necessary. Rated 3.0kW @ 240V.
Outer Casing White Plastisol with white high impact thermoplastic moulded top and bottom covers.
Thermal Insulation CFC/HCFC free (ODP ZERO) fire retardant expanded polyurethane. Nominal 50mm thickness.
Inner Container High Grade stainless steel, pressure tested to 15 bar.
Primary Coil 22mm diameter stainless steel. Coil-in-coil design for improved performance.
Thermostat Element thermostat adjustable from 10°C to 70°C.
Safety Features All Models: Temperature and pressure relief valve, factory set to operate at 10 bar and 90°C. High limit thermostat, factory set at 80°C.
Direct Models: Manually re-settable cut-out, set to 80°C.
Anode None required.
Approvals CE marked. kiwa approved to Water Regulations and Building Regulation G3. Manufactured in the UK in an ISO 9001:2000 registered factory.
INSTALLATION
Unvented units over 15 litre capacity must be installed by a competent installer in accordance with Local Regulations:
England & Wales – Building Regulation G3. Scotland – Technical Standards P3. N. Ireland – Building Regulation P5.
Fixing Feet on bottom moulding for floor mounting.
Plumbing Connections Inlet/Outlet 22mm compression fittings / 3/4” BSP parallel thread. |
Indirect Coil 22mm compression fittings / 3/4” BSP parallel thread.
Temperature and Pressure Relief Valve 15mm compression outlet.
Cold Water Control Integrated cold water control set comprising pressure reducing valve and strainer – factory set at 3.5 bar, expansion relief valve – factory set at 6 bar and check valve. 22mm compression fittings. Mains pressure: Min 1.0 bar, Max 16 bar. A 2-port Danfoss motorised valve is supplied with Indirect models.
Operating Pressure 3.5 bar.
Expansion Relief Valve Pressure 6.0 bar.
Operating Temperature Recommended 60°C. Adjustable 10 - 70°C.
Water Expansion Remote expansion vessel – 12 litre vessel supplied with 100, 120 and 150 litre models. 18 litre vessel supplied with 170 and 210 litre models. 25 litre vessel supplied with 250 and 300 litre models.
Minimum Water Supply Requirements Recommended minimum supply pressure – 1.5 bar/20 l/min flow rate.
If there are any doubts about water supply pressure or flow rates, please contact 0845 026 4620.
Secondary Circulation Via 22 x 22 x 15mm swept tee, which should be fitted to the inlet pipework.
Secondary circulation is NOT recommended for direct electric units being used on off-peak electricity tariffs.
Pressure Testing Units are tested to 15 bar.
Compatible Boilers Electric, gas or oil fired – open vent or sealed system type, fitted with integral control thermostat and cut-out.
Tundish 15mm compression inlet and 22mm compression outlet. |
ELECTRICAL
Direct Models: Connection is to the combined thermostat/thermal cut-out, housed within the integrated controls housing. The electrical supply must be permanently connected via a double pole linked isolating switch with a minimum break capacity of 13A.
Indirect models: Controls should be wired to the boiler, programmer etc. in accordance with the control scheme being used.
All electrical wiring must conform to the latest IEE Wiring Regulations.
GUARANTEE
The Pullin Evolution stainless steel vessel carries a full 10 year parts guarantee which includes:
Each unit is guaranteed against faulty manufacture or materials provided that:
-
It has been correctly installed as per the instructions contained in the instruction manual and all relevant Codes of Practice and Regulations in force at the time of installation.
-
It has not been modified in any way, other than by Pullin.
-
It has not been frost damaged.
-
It has only been used for the storage of potable water.
-
It has not been tampered with or been subjected to misuse or neglect.
-
Within 60 days of installation the user completes and returns the certificate supplied along with the proof of purchase to register the product.
-
It has been installed in the United Kingdom.
Expansion vessel is guaranteed for a period of 2 years from the date of purchase. The Pullin components, immersion heater and thermal controls are guaranteed for a period of 2 years from the date of purchase. Evidence of purchase and date of supply may be required. The unit is not guaranteed against damage due to frost. The guarantee is transferable. This guarantee does not affect your statutory rights. |