Unvented Cylinders
 
Pullin evolution unvented cylinders offer mains pressure water heating and are available in capacities from 100 to 300 litres, in both Direct and Indirect models.

They are manufactured from high-grade stainless steel and offer high levels of corrosion resistance for a long life. The design of the primary coil and cold-water controls gives fast re-heat and good flow rates. Pullin Evolution cylinders provide mains pressure showering and are suitable for use in both new build and refurbishment schemes and for domestic or commercial applications.

The cylinders have 50mm of foam insulation to give improved insulation standards. Outer casings are finished in white Plastisol with white high impact thermoplastic moulded top and bottom covers.
 
BENEFITS OF EVOLUTION
COMPLETE PACKAGE INCORPORATES SAFETY AND HOT WATER CONTROLS.
SAVINGS ON INSTALLATION FROM SIMPLIFIED PLUMBING AND ELECTRICAL CONNECTIONS.
NO ANODE TO MAINTAIN OR REPLACE.
FULLY FACTORY TESTED FOR RELIABILITY.
FAST RECOVERY RATES.
10 YEAR PARTS GUARANTEE ON CYLINDER.
2 YEAR PARTS GUARANTEE ON EXPANSION VESSEL.
2 YEAR PARTS GUARANTEE ON ELEMENT AND ALL OTHER CONTROLS
BENEFITS OF UNVENTED
MAINS PRESSURE HOT WATER FOR BALANCED SUPPLY TO SHOWERS AND MIXERS – NO SHOWER PUMP TO CONSIDER.
NO COLD FEED CISTERN REQUIRED.
NO HEAD PROBLEMS.
SAFE, ECONOMICAL PERFORMANCE.
NO LOFT PIPES TO FREEZE UP.
FLEXIBLE SITING OF CYLINDER INSTALLATION.
UK MANUFACTURED AND TESTED
Pullin Evolution cylinders are manufactured in the UK in an ISO 9001:2000 factory with each unit being pressure tested to 15 bar to ensure maximum safety. All Pullin Evolution units have integrated thermostatic controls and thermal cut outs for both direct and indirect heating. A factory fitted temperature and pressure relief valve provides a further level of thermal safety.
INSTALLATION AND CONNECTIONS
In order to give easy access to the cylinder during installation all of the plumbing and electrical connections are located at the front of the unit. In addition the electrical connections are made to an integrated wiring centre which allows for a neater and simpler installation. Plumbing connections are 22mm compression.
‘COIL IN COIL’ TECHNOLOGY – INDIRECT UNITS
The Pullin Evolution heat exchanger has a ‘coil in coil’ design which allows for a fast re-heat when water is used. Situated at the base of the unit, the heat exchanger ensures nearly all of the water is heated.
COLD WATER CONTROLS
Each unit is fitted with a cold-water control set which incorporates a pressure reducing valve and strainer, expansion relief valve and check valve. By incorporating three components into one installation time is reduced and the flow rate is improved across a range of inlet pressures.
GUARANTEE
Pullin Evolution units come with a 10-year parts guarantee for the cylinder and 2 years parts guarantee on the expansion vessel and all other valves and fittings.
 
SELECTION GUIDE
Property type
Indirect model
Direct model

 

 

 
Bedsit
100I or 120I
100D or 120D
 
1 or 2 bed with 1 bath or shower
150I
150D or 170D
 
3 bed with 1 bath or shower
170D or 210D
150D or 170D
 
4 bed with 1 bath or shower
170I or 210I
210D or 250D
 
2 or 3 bed with 2 baths or shower
210I
210D or 250D
 
4 or 5 bed with 2 baths or shower
210I or 250I
250D or 300D
 
4 or 5 bed with 3 baths or shower
250I or 300I
300D
 
Light commercial usage
250I or 300I
250D or 300D
 
Note:
All sizings calculated using BS6700
60 ltr hot water per bath
60 ltr hot water per shower
15 ltr hot water per sink
7 ltr hot water per basin
This selection chart is for guidance only. Hot water requirements will vary dependent on bath size, usage patterns, etc.
Technical Specification
 
MODEL
PRIMARY FLOW
HEAT UP TIME
FROM COLD
THROUGH 45°C
RECOVERY TIME
FOR 70%
DRAW-OFF
HOT WATER
DRAW-OFF
CAPACITY
AVAILABLE
AS HOT WATER
COIL OUTPUT
 
(litres/min
@ 80°C +/-2°C)
(mins)
(mins)
(litres)
(%)
(kW)
INDIRECT UNITS USING PRIMARY HEATING COIL
PE100I
15
26
20
87
87
11.2
 
PE120I
15
28
23
102
85
11.9
 
PE150I
15
28
22
134
89
15.6
 
PE170I
15
32
25
145
86
15.2
 
PE210I
15
36
27
188
89
17.4
 
PE250I
15
40
29
226
90
19.0
 
PE300I
15
47
35
271
91
19.0
 

 
INDIRECT UNITS USING ELEMENT ONLY
PE100I
 
84
 
 
 
 
 
PE120I
 
105
 
 
 
 
 
PE150I
 
137
 
 
 
 
 
PE170I
 
158
 
 
 
 
 
PE210I
 
200
 
 
 
 
 
PE250I
 
242
 
 
 
 
 
PE300I
 
294
 
 
 
 
 

 
DIRECT UNITS USING LOWER ELEMENT ONLY
PE100D
 
89
68
85
85
 
 
PE120D
 
110
83
105
88
 
 
PE150D
 
142
105
135
90
 
 
PE170D
 
163
120
155
91
 
 
PE210D
 
205
150
195
93
 
 
PE250D
 
247
183
235
94
 
 
PE300D
 
299
220
285
95
 
 


PULLIN EVOLUTION TECHNICAL SPECIFICATION
Nominal Capacities
100, 120, 150, 170, 210, 250 & 300 litres.
Element
Long-life Incoloy 800 sheathed element, incorporated into an easily removable heater plate, should replacement be necessary.
Rated 3.0kW @ 240V.
Outer Casing
White Plastisol with white high impact thermoplastic moulded top and bottom covers.
Thermal Insulation
CFC/HCFC free (ODP ZERO) fire retardant expanded polyurethane.
Nominal 50mm thickness.
Inner Container
High Grade stainless steel, pressure tested to 15 bar.
Primary Coil
22mm diameter stainless steel.
Coil-in-coil design for improved performance.
Thermostat
Element thermostat adjustable from 10°C to 70°C.
Safety Features
All Models:
Temperature and pressure relief valve, factory set to operate at 10 bar and 90°C. High limit thermostat, factory set at 80°C.
Direct Models:
Manually re-settable cut-out, set to 80°C.
Anode
None required.
Approvals
CE marked.
kiwa approved to Water Regulations and Building Regulation G3.
Manufactured in the UK in an ISO 9001:2000 registered factory.
INSTALLATION
Unvented units over 15 litre capacity must be installed by a competent installer in accordance with Local Regulations:
England & Wales – Building Regulation G3.
Scotland – Technical Standards P3.
N. Ireland – Building Regulation P5.
Fixing
Feet on bottom moulding for floor mounting.
Plumbing Connections
Inlet/Outlet
22mm compression fittings / 3/4” BSP parallel thread.
Indirect Coil
22mm compression fittings / 3/4” BSP parallel thread.
Temperature and Pressure Relief Valve
15mm compression outlet.
Cold Water Control
Integrated cold water control set comprising pressure reducing valve and strainer – factory set at 3.5 bar, expansion relief valve – factory set at 6 bar and check valve. 22mm compression fittings.
Mains pressure: Min 1.0 bar, Max 16 bar.
A 2-port Danfoss motorised valve is supplied with Indirect models.
Operating Pressure
3.5 bar.
Expansion Relief Valve Pressure
6.0 bar.
Operating Temperature
Recommended 60°C. Adjustable 10 - 70°C.
Water Expansion
Remote expansion vessel – 12 litre vessel supplied with 100, 120 and 150 litre models. 18 litre vessel supplied with 170 and 210 litre models. 25 litre vessel supplied with 250 and 300 litre models.
Minimum Water Supply Requirements
Recommended minimum supply pressure – 1.5 bar/20 l/min flow rate.
If there are any doubts about water supply pressure or flow rates, please contact 0845 026 4620.
Secondary Circulation
Via 22 x 22 x 15mm swept tee, which should be fitted to the inlet pipework.
Secondary circulation is NOT recommended for direct electric units being used on off-peak electricity tariffs.
Pressure Testing
Units are tested to 15 bar.
Compatible Boilers
Electric, gas or oil fired – open vent or sealed system type, fitted with integral control thermostat and cut-out.
Tundish
15mm compression inlet and 22mm compression outlet.
ELECTRICAL
Direct Models:
Connection is to the combined thermostat/thermal cut-out, housed within the integrated controls housing. The electrical supply must be permanently connected via a double pole linked isolating switch with a minimum break capacity of 13A.
Indirect models:
Controls should be wired to the boiler, programmer etc. in accordance with the control scheme being used.
All electrical wiring must conform to the latest IEE Wiring Regulations.
GUARANTEE
The Pullin Evolution stainless steel vessel carries a full 10 year parts guarantee which includes:
  • A dedicated customer service helpline to assist with guarantee issues.
  • Speedy dispatch of spares in the event of parts needing replacement.
Each unit is guaranteed against faulty manufacture or materials provided that:
  • It has been correctly installed as per the instructions contained in the instruction manual and all relevant Codes of Practice and Regulations in force at the time of installation.
  • It has not been modified in any way, other than by Pullin.
  • It has not been frost damaged.
  • It has only been used for the storage of potable water.
  • It has not been tampered with or been subjected to misuse or neglect.
  • Within 60 days of installation the user completes and returns the certificate supplied along with the proof of purchase to register the product.
  • It has been installed in the United Kingdom.
Expansion vessel is guaranteed for a period of 2 years from the date of purchase. The Pullin components, immersion heater and thermal controls are guaranteed for a period of 2 years from the date of purchase. Evidence of purchase and date of supply may be required. The unit is not guaranteed against damage due to frost. The guarantee is transferable. This guarantee does not affect your statutory rights.

DIMENSIONS
 
MODEL
A
(mm)
B
(mm)
C
(mm)
D
(mm)
 
PE100D
 
306
493
784
 
PE100I
315
354
493
784
 
PE120D
 
306
615
906
 
PE120I
315
354
615
906
 
PE150D
 
306
800
1090
 
PE150I
315
354
800
1090
 
PE170D
 
306
925
1216
 
PE170I
315
354
925
1216
 
PE210D
 
306
1184
1474
 
PE210I
315
354
1184
1474
 
PE250D
 
306
1391
1726
 
PE250I
315
354
1391
1726
 
PE300D
 
306
1715
2040
 
PE300I
315
354
1715
2040
 
Solar Cylinders
 
Pullin Evolution Solar cylinders have been designed for use with a variety of UK solar systems and offer all the same features as the standard Pullin Evolution cylinders but with the additional benefit of lower running costs. The range includes 190, 210, 250 and 300 litre models in both direct and indirect versions.

In order to ensure maximum heat gain each cylinder is fitted with a solar coil which has been designed specifically for use with solar systems.
 
BENEFITS OF EVOLUTION SOLAR

UNVENTED WATER HEATING.

SOLAR COIL FOR MAXIMUM HEAT GAIN.

COMPATIBLE WITH RANGE OF SOLAR SYSTEMS.

ALL THE BENEFITS OF PULLIN EVOLUTION CYLINDERS.

BENEFITS OF SOLAR

ENVIRONMENTALLY FRIENDLY.

LOWER RUNNING COSTS AND REDUCED ENERGY BILLS.

REDUCED CARBON EMISSIONS.

WHICH SOLAR UNIT TO USE

The choice of capacity for traditional cylinders is based on the hot water requirements of the dwelling. With solar cylinders the usable hot water will vary due to a number of factors such as siting of solar panels, time of year and weather conditions. For this reason, when choosing a solar cylinder you should ensure that sufficient usable hot water will be available during winter months where solar gain is at its lowest. For example a non-solar dwelling of 3 inhabitants with a bath and a shower would normally require a 145 litre indirect cylinder. However, in line with the ClearSkies* recommendation, at least 30% of the cylinder capacity must be dedicated to solar, therefore the same dwelling with a solar system would require a 210 litre indirect solar cylinder which would provide 143 litres of hot water during periods where there is little or no solar gain. For guidance please refer to the table below. Some applications may require larger water quantities or higher recovery rates, therefore it is important to calculate the hot water requirement before selecting the cylinder capacity.

SOLAR CYLINDER CAPACITIES
MODEL TOTAL SOLAR
HEATED CAPACITY
LITRES
AUXILIARY TOP-UP
HOT WATER CAPACITY
LITRES



190I SOLAR 190 122
210I SOLAR 210 143
250I SOLAR 250 175
300I SOLAR 300 210
190D SOLAR 190 122
210D SOLAR 210 143
250D SOLAR 250 175
300D SOLAR 300 210

SIZING GUIDANCE – SOLAR CYLINDERS
APPLICATION INDIRECT
CAPACITY
LITRES
DIRECT
CAPACITY
LITRES



Bedsit 190 190
1 bed 1 bath & 1 shower 190 190
2 bed 1 bath & 1 shower 190 210
3 bed 1 bath & 1 shower 210 250
4 bed 1 bath & 1 shower 210/250 250/300
4 or 5 bed 2 bath & shower 250/300 300
4 or 5 bed 3 bath & shower 300 n/a†

† For high demand direct auxiliary heating applications and other commercial uses, cylinders can be linked to provide larger capacity output.

Figures are for guidance only and are based on BS6700 recommendations.
BS6700 gives recommendations for water supply for domestic use. Some applications may require larger water quantities or higher recovery rates and so should be individually calculated to ensure the correct size unit is selected. Actual usage requirements should be assessed in selecting the correct cylinder.

Technical Specifications
 
SOLAR TECHNICAL SPECIFICATION

Nominal Capacities
190, 210, 250 & 300 litres.

Solar Coil
25mm diameter stainless steel.
Coil-in-coil design and large surface area for improved performance.

A pocket is provided for solar controls suitable for insertion of solar controller temperature probe.

A 2-port motorised valve is supplied with twin coil models to provide over-temperature protection when heating using the auxiliary heating (boiler) coil.

ClearSkies accredited.


SOLAR INSTALLATION

Solar Coil
22mm compression fittings / 3/4” BSP parallel thread.

Water Expansion
Remote expansion vessel – 25 litre expansion vessel supplied with all solar models.


Evolution Solar Direct

Evolution Solar Indirect

DIMENSIONS
MODEL A
(mm)
B
(mm)
C
(mm)
D
(mm)
E
(mm)
F
(mm)
G
(mm)
PE190I SOLAR 732 803 1017 1137 1401
PE210I SOLAR 892 808 1054 1181 1502
PE250I SOLAR 1140 868 1256 1376 1760
PE300I SOLAR 1438 1024 1571 1692 2067
PE190D SOLAR 1137 1401 754 900
PE210D SOLAR 1181 1502 759 1001
PE250D SOLAR 1376 1760 819 1259
PE300D SOLAR 1692 2067 975 1566
 (Click on links below to view)