Hot Water Cylinders
Search
0 ITEM(S) IN YOUR BAG / TOTAL:£0.00   view cart

Dualstream Water Control
Item Id: 4976
Dualstream Water Control
Email this page to a friend Be the first to review this item
Price
Your Price:
£1,070.88
Availability:
Not for Sale
Choose Options and Quantity
Unvented Cylinder Direct Range
Direct Range Options TDD 200-125
TDD 240-150 [+£92.07]
TDD 240-150 [+£88.67]
TDD 300-210 [+£160.28]
TDD 300-300 [+£369.69]
TDD 500-300 [+£515.65]
TDD 500-500 [+£713.46]
Unvented Cylinder Indirect Range
Indirect Range Options TDI 200-125
TDI 200-210 [+£92.07]
TDI 240-150 [+£88.67]
TDI 300-210 [+£160.28]
TDI 300-300 [+£369.69]
TDI 500-300 [+£515.65]
TDI 500-500 [+£713.46]
Description

 

Why choose a Dualstream system?

  • No cistern in the loft - no risk of water stagnation, Legionella and frost damage
  • Greater plumbing designs, uses less pipe-work, saving time and money
  • Wholesome water to all cold taps and balanced hot and cold water supplies
  • Dualstream utilises one of the slimmest and highest volume yielding unvented cylinders on the market
  • Will provide a substantial increase in water volume, to both hot and cold-water outlets, with-in the building
  • Will work at very low flow rates (9 l/mm) 1 Bar (min Water Board supply requirements)
  • Sized correctly the system will fill any number of baths simultaneously and ideal for multi-bathroom dwellings
  • True 'power shower' performance without the need of pumps
  • Overcomes problems associated with low mains pressure or inadequate flow rates
  • Efficient insulation, low power consumption. All unvented cylinders are insulated with high density CFC free insulation.
  • Can replace the need for high maintenance noisy break tanks and booster pump sets
  • Accumulators and cylinders can be linked together for greater demands, for the larger properties, small hotels and leisure and sports clubs
  • Indirect Models from 125 - 500 litres (heated from a boiler source)
  • Direct Models from 125 - 500 litres (heated from electric immersion)
  • Accumulator models from 100 - 500 litres
  • Twin coil cylinders available on request
  • Immersion heater upgrades available
  • Unvented stainless steel cylinders up to 300 litres with 25 year warranty
  • All electrical components are covered by 2 year warranty
  • Accumulators have longest industry warranty at 5 years
The Dualstream System
The Dualstream systems by GAH Heating Products have been developed as an advanced
solution for domestic hot and cold water installations. A Dualstream system will increase
the water volume and maintain the mains pressure to both the hot and cold supplies,
even when more than one outlet is in use at the same time.
Dualstream has been designed to function on the minimum standard for domestic water
supply as provided by local water authorities - which is 1 Bar at 9 litres per minute.
GAH offer full technical assistance and design service to enable the optimum Dualstream
system to be configured to overcome situations where poor mains supply and pressure
are considered a problem.
 
How the Dualstream system works
The system mainly comprises:- an unvented direct or indirect cylinder, an accumulator
(cold water storage vessel), a combination valve and an expansion relief valve.
The accumulator has an internal controlled butyl diaphragm, incoming cold water is
stored within this diaphragm at mains pressure. The air space between the diaphragm
and the accumulator case is pressurised, this balances the supply and maintains
pressure to the unvented hot water cylinder and cold outlets. When hot and cold water
outlets are turned on the stored water from the accumulator supplements water from the
incoming main, this results in consistent pressure and flow to all taps, showers and baths
even when outlets are used simultaneously. Pressure will be sustained for as long as the
accumulator is holding suffficient volume of water.
 
Please View the PDF Below for more Information
 

TDD 200-125

 

The code number refers to the cylinder sizes TDD 200-125 (Model code TDD = Direct), 200 litre accumulator followed by 125 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

125

¾

 

 

150 min

3kW+3kW

70°C

650

755

955

 

505

265

 

138

 

 

TDD 200-210

 

The code number refers to the cylinder sizes TDD 200-210 (Model code TDD = Direct), 200 litre accumulator followed by 210 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

200

¾

 

 

240 min

3kW+3kW

70°C

940

1230

1475

 

505

265

 

220

 

 

TDD 240-150

 

The code number refers to the cylinder sizes TDD 240-150 (Model code TDD = Direct), 240 litre accumulator followed by 150 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

150

¾

 

 

175 min

3kW+3kW

70°C

790

915

1155

 

505

265

 

164

 

 

TDD 300-210

 

The code number refers to the cylinder sizes TDD 300-210 (Model code TDD = Direct), 300 litre accumulator followed by 210 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

200

¾

 

 

240 min

3kW+3kW

70°C

940

1230

1475

 

505

265

 

220

 

 

TDD 300-300



The code number refers to the cylinder sizes TDD 300-300 (Model code TDD = Direct), 300 litre accumulator followed by 300 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

300

¾

 

 

350 min

3kW+3kW

70°C

1215

1555

1790

 

560

275

 

331

 

 

TDD 500-300

 

The code number refers to the cylinder sizes TDD 500-300 (Model code TDD = Direct), 500 litre accumulator followed by 300 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

300

¾

 

 

350 min

3kW+3kW

70°C

1215

1555

1790

 

560

275

 

331

 

 

TDD 500-500

 

The code number refers to the cylinder sizes TDD 500-500 (Model code TDD = Direct), 500 litre accumulator followed by 500 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

495

1

 

 

290 min

6kW

70°C

1390

335

1870

 

714

 

 

630

 

 

 

Unvented Cylinder Indirect Range

 

 

 

TDI 200-125

 

The code number refers to the cylinder sizes TDI 200-125 (Model code TDI = Indirect), 200 litre accumulator followed by 125 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

125

¾

0.75

20.5

18 min

3kW

70°C

650

755

955

625

505

265

225

143

 

 

TDI 200-210

 

The code number refers to the cylinder sizes TDI 200-210 (Model code TDI = Indirect), 200 litre accumulator followed by 210 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

200

¾

0.9

26.7

26 min

3kW

70°C

940

1230

1475

765

505

265

225

227

 

 

TDI 240-150

 

The code number refers to the cylinder sizes TDI 240-150 (Model code TDI = Indirect), 240 litre accumulator followed by 150 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

150

¾

0.9

26.7

22 min

3kW

70°C

790

915

1155

765

505

265

225

171

 

 

TDI 300-210

 

The code number refers to the cylinder sizes TDI 300-210 (Model code TDI = Indirect), 300 litre accumulator followed by 210 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

200

¾

0.9

26.7

26 min

3kW

70°C

940

1230

1475

765

505

265

225

227

 

 

TDI 300-300

 

The code number refers to the cylinder sizes TDI 300-300 (Model code TDI = Indirect), 300 litre accumulator followed by 300 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

300

¾

0.9

26.7

40 min

3kW

70°C

1215

1555

1790

815

560

275

255

337

 

 

TDI 500-300

 

The code number refers to the cylinder sizes TDI 500-300 (Model code TDI = Indirect), 500 litre accumulator followed by 300 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

300

¾

0.9

26.7

40 min

3kW

70°C

1215

1555

1790

815

560

275

255

337

 

 

TDI 500-500

 

The code number refers to the cylinder sizes TDI 500-500 (Model code TDI = Direct), 500 litre accumulator followed by 500 litre hot water cylinder.

Storage Capacity (litres)

inlet/outlet size (inches)

Coil Surface (m² )

Coil Rating (kW)

Reheat Time (∆T=50° C)

Element Power

Max. temp.

Dimensions in mm

Weight full (kg)

A

B

C

D

E

F

G

495

1

1.5

31.8

54 min

6kW

70°C

1390

335

1870

700

714

 

 

641