Enter your Email address below and press the GO button.
RMC Group Indirect 180L Cylinder
The RCM Group is now the largest manufacturer of cylinders in the UK and has used the same blueprint for its success in the development and production of its new stainless steel unvented range of cylinders.
They are designed specifically for the UKmarket made from high quality 'Duplex' stainless steel, backed by a fully transferable 25 year guarantee.
B
C
D
E
F
Weight (kg - empty)
Weight (kg - full)
90L
718
550
290
330
390
345
N/F
30
120
120L
906
35
155
150L
1093
370
465
385
40
190
180L
1281
45
225
210L
1469
365
405
1150
50
260
250L
1719
560
950
1400
55
305
300L
2032
660
1100
1600
60
360
What is mainspressure?These units allow you to connect the Ultrasteel directly to the mains via the safety valves provided. This allows you to have power showers without the need for noisy shower pumps and means no cold water cistern tanks are required in the loft.
Below are a number of examples, along with data to help you decide which unit is right for you. There are a number of points to consider along the way - firstly, how many major outlets for hot water do you have to supply? Baths require between 55 and 100 litres, Jacuzzis require up to 550 litres. (Baths allow 30 minutes duration).Small Showers require 7 litres per minute; High Volume Showers require 11 litres per minute. (Showers allow 10 minutes duration). Sinks require between 10 and 15 litres, Wash Basins require between 1 and 5 litres.
Direct
Indirect
Application
Commercial Selection Guide
Flat
Large
6 Bedrooms / 4 Bathrooms
2 X 210L
1-2 Bedroom (1 bath/showers)
Guest House
8 Bedrooms / 4 Bathrooms
2 X 300L
3 Bedroom (1 bath/showers)
Small Hotel
8 Bedrooms / 8 Bathrooms
3 X 210L
4 Bedroom (1 bathroom/showers)
Sports Pavilion
25 People / 4 Showers
4-5 Bedroom (2 baths/showers)
25 People / 6 Showers
4-6 Bedroom (3 baths/showers)
Student House
25 People / 3 Bathrooms
3 X 300L
5-6 Bedroom (3 Baths/Showers)
Old People’s Home
60 Bedrooms / 10 Bathrooms
5 X 300L
Indirect Re-heat Coil kw Direct Re-heat Time One Element Re-heat Time Two Elements 90L 13 Minuets 16.5 90L 58 Minuets - 120L 17 Minuets 16.5 120L 90 Minuets 45 Minuets 150L 17 Minuets 18.9 150L 121 Minuets 61 Minuets 180L 21 Minuets 18.9 180L 151 Minuets 79 Minuets 210L 22 Minuets 18.9 210L 192 Minuets 96 Minuets 250L 28 Minuets 21.4 250L 224 Minuets 112 Minuets 300L 36 Minuets 21.4 300L 263 Minuets 132 Minuets
Re-heat
Coil kw
Re-heat Time One Element
Re-heat Time Two Elements
13 Minuets
16.5
58 Minuets
-
17 Minuets
90 Minuets
45 Minuets
18.9
121 Minuets
61 Minuets
21 Minuets
151 Minuets
79 Minuets
22 Minuets
192 Minuets
96 Minuets
28 Minuets
21.4
224 Minuets
112 Minuets
36 Minuets
263 Minuets
132 Minuets
For applications where very high flow rate or larger amounts of storage are required two or more Ultrasteel units can be linked in parallel.When linking two cylinders a separate cold feed is taken to each one and the outlets are joined together. The flow rate available doubles (subject to the cold main).The demand for hot water will vary considerably between types of buildings and activities taking place there, for exampleAn office building will require small quantities frequently to many outlets during normal and overtime office hours.A factory production line will have a peak demand at the breaks in the shift or at the end when the work force may all want to wash their hands simultaneously. A sports pavilion will need to be able to provide large quantities of hot water for the teams showering needs, over a short period of time after the game. So your selection must take into account a number of things:1) The maximum simultaneous hot water demand2) The total hot water demand required3) The required system reheat time
Taking Responsibility
We are very aware of of our long term responsibility to the planet and are doing everything possible to improve our contribution to this cause. We have chosen materials that will genuinely last a lifetime and have avoided producing the steel and glass lined units favoured by other manufacturers which typically offer a much reduced life expectancy.
Duplex stainless steel is extremely environmentally friendly. As a material it is 100% recyclable in fact over 90% of new stainless steel comes from old re-melted stainless steel. Stainless steel will go on to complete full life cycles indefinitely.
The performance of the unit with its “coil within a coil” gives fast recovery to 100% of the water content of the unit and not just part volumes like many on the market. Link this with our 50mmCFC/HCFC free (ODP Zero) foam injection lagging which gives maximum heat retention and you have a range that is very efficient and will save money on fuel bills.
Being Committed
Our commitment goes much further than just the present, as we are constantly developing new products in the same vein. These products go towards developing renewable energy resources such as solar, wind and geothermic power which we can utilise with our high recovery twin coiled units.
Continually Evolving
All in all we take environmental issues very seriously when others just pay it lip service, and we will continue to improve and develop our processes and products to keep our self-imposed high standards in this field.
Copyright 2000 - 2009, hot-water-cylinders.com
Pay securely with any major credit card with secpay Lloyds TSB.
Email: sales@hot-water-cylinders.com